Share. In 4219's with 8 dip switches, #6 will always be ON for these panels. Dip switch can stay on to keep tamper disabled. https://uploads.disquscdn.com/images/eb277c1b9f8f8055a5ed23021b5a44579b8853278a0a3c2dd79e12c8f6064e18.png. Did Honeywell change the design and increase the contact rating on newer expansion module relays? Connection made to the control's console wires. There is a difference between having a 5883H and using a combination of a 5881ENH/5800TM though. Title: Wiring & Setup of 4219/4229 Zone Expanders . My setup seems to work with the COSMOD4W. Of course the 4208SN uses 10k resistors that are all EOL way up high in motions. The zones on the panel are able to handle this and signal the alarm. After physically setting the zone expanders (7&8 respectively), how does this get reflected or programmed into the actual panel? I also have a new model 4229 which is also exhibiting the same behavior to me. Anything that you'd like triggered can be triggered by these relays in the event of an alarm. Is there a technical reason that the 4229 doesn't work with carbon monoxide detectors, or why they just say it doesn't work with "some"? The module may be mounted within the control's cabinet (if, room permits), or remotely. 3. The 4120TR is a wiring harness that will connect to the trigger pins via a plug. Locate anywhere on the addressable ECP bus Compatibility: UL Listed for commercial burglary applications Yay! Located across from the Doana National Park, on the left bank of the Guadalquivir river, this town is famous for its "manzanilla" sherry cellars, and the horse races at the beach. The module may be mounted within the control's cabinet (if. Use the CO2 calculator to find out the carbon footprint of your trip and reduce your emissions. External power supply option: 100mA at 12VDC (maximum) PDF Wired Zone Expander/Relay Module tapping screws (provided) in two adjacent raised tabs at the, back of the cabinet. Please include what you were doing when this page came up and the Cloudflare Ray ID found at the bottom of this page. When the module is to be mounted inside the control's. However, as I'm not quite sure how those contacts appear to the Vista, those "different options" could just be monkeys on a keyboard, aka, random attempts. Towns and villages on the Andalusian Coast where you can disconnect. It is very common to run out of wired zone inputs on a Honeywell VISTA System, so being able to add more with a device like the Honeywell 4229 can be very important. Description: Addressable eight-zone expander with two relay outputs for Honeywell ECP bus addressable systems Product advantages. I am about to start a job where the customer has a old vista 20se panel, and needs to replace with a vista 15p panel. 4229 Installation manualOld 4229 Installation manual4229 Data sheet. Honeywell Ademco 4229 Wired Zone Expander/Relay Board Model: 4229 The origins of the city centre go back to Muslim times, as can be observed in the present appearance, with its narrow streets, zigzagging . Good: Provides 8 Wired Zone Inputs, 2 Relay Outputs, Includes Resistors, Bad: Doesn't Actually Add More Zones, Does Not Support Life-Safety Sensors, Wiring Not Included, Draws Power From Panel. Details, Published: The 4229 needs a minimum of 12Vdc to operate and the COSMOD2W requires a minimum of 12.p Vdc. I then programmed (*79/80) the 01 output to address the 4229 [08] and have the 01 output function as 'Fire Zone reset' (54). PDF 4219 Wired Zone Expander Module INSTALLATION AND SETUP GUIDE Thanks for the info Julia! AD12612 Installation manualAD12612 Data sheet. Free technical and programming support. 4219 Wired Zone Expander Module INSTALLATION AND SETUP GUIDE GENERAL INFORMATION This module adds up to eight end-of-line resistor supervised zones to compatible control/communicators via the control s keypad wiring. The The HONEYWELL-ADEMCO-4229 is a wired zone expander/relay board that provides 8 end-of-line supervised zones and two on-board programmable Form C relays. You will get 8 additional hardwired zones on the 4229 and you will also get two relays that can be used to trigger external devices such as extra sirens, strobes, or external lighting. cabinet, it should be mounted horizontally. the ability to add multiple zone expanders to gain more hardwired zones offers maximum protection with . 4229 Wired zone expander with 8 hardwired zones with 2 relay Brand: HONEYWELL HOME RESIDEO. Ademco 4219/4229 Zone Expander - Vyanet Operating Group Find information on our airports and cruise ports and discover what the flight times are from different points across the world. # 1 05-07-11, 09:40 AM P pepitopty Member Thread Starter Join Date: Apr 2010 Location: Panama Posts: 36 Upvotes: 0 Received 0 Upvotes on 0 Posts Ademco 4229 Zone Expander Hello, Finally I got my 4229 zone expander all connected. Resistors are required, not optional. Check with your company admin to get an invite to your company's profile, then create your own account. The 4229 Zone Expander with Relays is just that; a zone expander with built-in relays. The 5883H contains the same internal guts as a 5881ENH wireless receiver and a 5800TM wireless transmitter. Any suggestions? Love your existing devices? the installation instructions for that control unit. In one, dip 7 should always be on, and 2K End of Line Resistors must be used. What do you mean by "hit a door?" Screen displays "01 Rly Position" "1-4" (note: this should only have a choice of 1-2, do not try to set up a relay 3 or 4, address . For instance if you need more hardwired zones for your system than the initial 6 or 8 that come standard on the control board; you can add either the 4219 Zone Expander or the 4229 Zone Expander.Both of these will add 8 more hardwired zones to your alarm panel but the 4229 has two on . So if you set the 4219 to address 7, thats zones 9-16 so you'll be able to program a zone 9 AW Type zone and not have any issues as long as the 4219 is set for address 7 and things are wired up properly. Do you want to know the entry ticket price for Tajos De Mogarejo? I bought them at separate times, so the Honeywell version has 8 dip switches and the older Ademco unit has 5. With SW1 open (OFF) and SW2 open (OFF), the power supply has a 12VDC output voltage. The power wires are not shown going all the way to the screw terminals so that you can see the terminal markings, but obviously, these should be connected to those screws. Central Station Alarm Monitoring Services, Total Connect 2.0 Package Monitoring Add-Ons. See the control's instructions for additional, When the module is to be mounted remotely , holes on its, back permit it to be mounted horizontally or vertically. These modules had 8 dip switches, used 2k resistors, but the EOL resistors were still required, not optional (dip switch 7 must remain ON). This board does requires a power transformer and system backup battery, cabinet optional. Its most attractive features include its mild climate, the beaches of Bajo de Gua, Calzada, Las Piletas and La Jara, as well as numerous monuments, such as the castle of Santiago, from the 15th century; the palace of the Infantes of Orleans and Borbn, present site of the City Hall; the church of Nuestra Seora de la O; the palace of the dukes of Sidonia, which at present houses the municipal archives; and the convent of Santo Domingo, from the 16th century. It would automatically reflect into the panel. I'm pretty sure you're correct, so turn on Dip 7, and be sure to use the 2K resistors, even if its just at the 4219 itself. . Older 4219's have five dip switches while newer models have eight. Get it Mar 27 - 30. Is that a good idea? Unfortunately, this results in a fault on Zone 17 where my smokes are wired. It can cause a lot of confusion. Leave the heads projecting 1/8". CO detectors sometimes cause a trouble condition prior to an alarm condition. IE 2k + 8.2 = 10.2k is the extra 200 ohms ok? You have been registered for product and offer updates. The contact rating at each relay is 2A at 28 Volts AC or DC. BRAND NEW. On the SMP3: With SW1 closed (ON) and SW2 open (OFF), the SMP3 has an output voltage of 6VDC. The Honeywell 4229 is an 8-zone wired expansion module with two (2) relay outputs. Specifically, it uses 30mA while the relays are inactive, and 100mA with active relays. D, Honeywell 4229 - Install Guide - Dated 03/14 Rev. Can you clarify what you have, and how you intend to use it? THANT Ask an Expert Electronics Question Home Security Questions 11,168 Read more: https://www.alarmgrid.com/faq/how-do-i-address-a-4219-zone-expander-to-a-vista-system AndyTech209 11,168 Satisfied Customers AndyTech209 is online now See the control's instructions, When the module is to be mounted remotely, holes on its, back permit it to be mounted horizontally or vertically. Zone numbers are based on the device addresses listed in the table below. Want to contact the Administration of Sanlcar de Barrameda? I love your videos. All of the, module's other protection zones have a nominal response, Connections to the module's two relays are made via the 7-, conductor cord provided. Thanks in advance. They do not stop us from rating the Honeywell 4229 with 5 Stars. If you have a 5839 keypad you will only be able to use the 5883H instead of using a paired 5881ENH\/5800TM.\u003cbr\u003e\u003cbr\u003eYou can pick up up to 40 wireless devices with this unit.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/5800-Receivers-Data-Sheet.PDF?14563690923375147551\" target=\"_blank\" title=\"5883H Data sheet\" rel=\"noopener noreferrer\"\u003e5883H Installation manual\u003cbr\u003e5883H Data sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2012-05-20T22:51:00-04:00","created_at":"2017-01-23T07:10:32-05:00","vendor":"Honeywell","type":"Honeywell Security Expansion Modules","tags":["Els PW 22614","Honeywell Expansion Modules","Honeywell Security","Honeywell Security Expansion Modules"],"price":26795,"price_min":26795,"price_max":26795,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":24526195205,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"5883H","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Honeywell 5883H Wireless Transceiver","public_title":null,"options":["Default Title"],"price":26795,"weight":907,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"5883H","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-322285.jpg?v=1595526198","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-717189.jpg?v=1595526199","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-331891.jpg?v=1595526199","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-775549.jpg?v=1595526199","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-255106.jpg?v=1595526199","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-540758.jpg?v=1595526199"],"featured_image":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-322285.jpg?v=1595526198","options":["Title"],"media":[{"alt":"Honeywell 5883H Wireless Transceiver - AlarmSystemStore.com","id":7363140485222,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-322285.jpg?v=1595526198"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-322285.jpg?v=1595526198","width":1024},{"alt":"Honeywell 5883H Wireless Transceiver - AlarmSystemStore.com","id":7363140616294,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-717189.jpg?v=1595526199"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-717189.jpg?v=1595526199","width":1024},{"alt":"Honeywell 5883H Wireless Transceiver - AlarmSystemStore.com","id":7363140649062,"position":3,"preview_image":{"aspect_ratio":1.499,"height":683,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-331891.jpg?v=1595526199"},"aspect_ratio":1.499,"height":683,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-331891.jpg?v=1595526199","width":1024},{"alt":"Honeywell 5883H Wireless Transceiver - AlarmSystemStore.com","id":7363140681830,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-775549.jpg?v=1595526199"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-775549.jpg?v=1595526199","width":1024},{"alt":"Honeywell 5883H Wireless Transceiver - AlarmSystemStore.com","id":7363140714598,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-255106.jpg?v=1595526199"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-255106.jpg?v=1595526199","width":1024},{"alt":"Honeywell 5883H Wireless Transceiver - AlarmSystemStore.com","id":7363140747366,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-540758.jpg?v=1595526199"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-5883h-wireless-transceiver-540758.jpg?v=1595526199","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003eHoneywell 5883H Wireless Transceiver\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003eThe 5883H combines the technology of a wireless receiver and a wireless transmitter. Make protection zone connections to 12-position terminal, block TB1. Make sure to accommodate for this and provide enough power for the relays to activate. This board can supplu 6 volts or 12 VDC at a max of 1.2 amps. The relay contacts will handle 2A @ 28VAC or DC (Resistive or Inductive loads). This is a great device to use if you need to add support for additional wired zones to your system, while also adding two extra programmable relay outputs. When changing dip switch settings, I recommend powering down, making the change, then powering back up. How many dip switches does each of your 4219's have, and if they both have 8, about how old is each one? The tamper jumper should be put into its lower, position and, when the installation is completed, the, module's cover put on. Odd I put back my working module and the zone is reporting fine. It only adds additional zone input terminals so that more hardwired zones can be used. Life-safety sensors, such as 2-wire smoke detectors and carbon monoxide sensors, should not be used with the Honeywell 4229, thereby representing another limitation. We test, inspect and restore all EPCOM products to working conditions. Wired Zone Expander / Relay Board Del Roco Sanlcar de bda.. Update: Per Honeywell Home Tech Support the COSMOD is okay on the 4219/4229. Honeywell Home 4229 Wired 8-Zone Expander Relay Board for ECP Bus Zone the latest products, and offers. Thanks! $34.60. Wires, can exit from the side or the breakout on the back of its. Each zone that is, used must have a 2K-ohm end-of-line resistor, connected across the end of its loop, as shown in, The method of programming each zone for type of alarm, and reporting code to the central monitoring station varies, with the control to which the module is connected. I'm still uncertain about the rating on the contact side. It provides terminals for 8 additional hardwired sensors and two relay outputs for providing power to external hardwired electrical devices, such as sirens. I'll try the new module again and delete the zone and added it back in. This item: Honeywell 4229 Ademco Wired Zone Expander and Relay Board. 2-wire photoelectric i3 series smoke detector with a 135F fixed thermal sensor, Alarm Panel Kit VISTA48LA with 9Ah Battery, Transformer and Cabinet, Proximity Reader with Keypad Outdoor/ Wiegand output. This means dip switches 2, 3, and 4 should be off, and dip switch 5 should be on. Make sure that dip switch 8 is on to disable the tamper, Hi Kiwi, what which Vista 250 are you going to? Extender Honeywell ADEMCO 4229 Installation Instructions. To add a second zone expander to a VISTA-20P: Configure the dip switches. General Information Name : Honeywell Home 4229 Wired 8-Zone Expander Relay Board for ECP Bus Zone VISTA Control Panels , Honeywell Home Category : Control Panel Modules UPC Code : 781410000889 Country of Origin : Mexico. The board does provide charge current to keep the backup battery charged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 6 or 12 VDC (6 or 12 volt operation)\u003c\/li\u003e\n\u003cli\u003e1.2 Amps continuous output to power devices\u003c\/li\u003e\n\u003cli\u003eTransformer purchased separately Factory preset at 13.6 VDC, with the jumper set to supply 12 volts DC\u003c\/li\u003e\n\u003cli\u003eUse transformer 1322\/TF3 for 6 volt operation1361 for 12 volts DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/AD12612_Installation-Instructions.PDF?8833695308316292152\" target=\"_blank\" title=\"AD12612 Installation manual\" rel=\"noopener noreferrer\"\u003eAD12612 Installation manual\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1659\/9809\/files\/AD12612_Cut-Sheet.PDF?8833695308316292152\" target=\"_blank\" title=\"AD12612 Data sheet\" rel=\"noopener noreferrer\"\u003eAD12612 Data sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2013-01-28T02:02:00-05:00","created_at":"2017-01-23T07:11:19-05:00","vendor":"Honeywell","type":"Honeywell Security Expansion Modules","tags":["Honeywell Expansion Modules","Honeywell Security","Honeywell Security Expansion Modules"],"price":3495,"price_min":3495,"price_max":3495,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":24526225669,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"Ademco-AD12612","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Honeywell Ademco 12612 Power Supply Board","public_title":null,"options":["Default Title"],"price":3495,"weight":454,"compare_at_price":null,"inventory_quantity":5,"inventory_management":"shopify","inventory_policy":"deny","barcode":"Ademco-AD12612","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-ademco-12612-power-supply-board-282147.jpg?v=1595526180","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-ademco-12612-power-supply-board-701886.jpg?v=1595526180","\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-ademco-12612-power-supply-board-987105.jpg?v=1595526180"],"featured_image":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-ademco-12612-power-supply-board-282147.jpg?v=1595526180","options":["Title"],"media":[{"alt":"Honeywell Ademco 12612 Power Supply Board - AlarmSystemStore.com","id":7363133014118,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-ademco-12612-power-supply-board-282147.jpg?v=1595526180"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-ademco-12612-power-supply-board-282147.jpg?v=1595526180","width":1024},{"alt":"Honeywell Ademco 12612 Power Supply Board - AlarmSystemStore.com","id":7363133079654,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-ademco-12612-power-supply-board-701886.jpg?v=1595526180"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-ademco-12612-power-supply-board-701886.jpg?v=1595526180","width":1024},{"alt":"Honeywell Ademco 12612 Power Supply Board - AlarmSystemStore.com","id":7363133145190,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-ademco-12612-power-supply-board-987105.jpg?v=1595526180"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/www.alarmsystemstore.com\/cdn\/shop\/products\/honeywell-ademco-12612-power-supply-board-987105.jpg?v=1595526180","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2\u003eHoneywell Ademco 12612 Power Supply Board\u003c\/h2\u003e\n\u003cp\u003eTheHoneywell Ademco 12612 Power Supply Board with charge circuit is commonly used when you need additional aux power for powered devices or additional sirens. I got 12 4229u zone expanders what are the dip switch settings for each of these? Panoramic view of Sanlcar de Barrameda in Cadiz (Andalusia). 2023 Resideo Technologies Inc. 1.2 Amps continuous output to power devices The resistors are important for letting the system know if someone tries to cut a sensor from the line. communicators via the control's keypad wiring. Temperature: The address and dip switch settings depend on which panel as well as which zone numbers are being used. Nothing changed with the wiring? Two disarms will clear a trouble if the issue has been fixed i have a check 107 wire expanson after we hit a door . See how we support your home and fit into your life. CHANGED ADDRESS TO 9 WITH EOL, TAMPER OFF. Dip switch 5 will need to be in the off position. 956 38 80 07. International: +34 956 38 80 07. If the, wiring is cut, a tamper or alarm signal will result, to indicate, that this device (and possibly other similarly connected, IMPORTANT: Some carbon monoxide detectors may not be, compatible with the ADEMCO 4229 hardwire zone, expanders. If you don't wish to use the cover tamper, be sure the jumper is on the 2 pins closest to the middle of the board. When using carbon monoxide detectors in, systems that support the 4229 zone expanders, install the, detectors only on the basic hardwire zones of the system. Addressing the 4219 is done through dip switches. 2. I wanted the extra zones for some interior contacts for home automation ideas. As noted above, dip switch 6, in Refer to. 5-95% relative, non-condensing, We'll let you know when this products arrives, Mini Domo IP PTZ 2MP / 30m IR / 4X Zoom Optico / Da/Noche ICR Real / PoE+, Addressable eight-zone expander with two relay outputs for Honeywell ECP bus addressable systems Product advantages, Can be located anywhere along the four-wire addressable ECP bus, Adds up to eight class B zone inputs to an ECP bus addressable system, each with 1K end-of-line resistors, Class B loops provide a broad, 300 ohm tolerance, Supervised for open, shorted or normal circuit conditions, Add up to two relay outputs to the system, UL Listed for commercial burglary applications, On a flat surface, centrally located to collect up to eight zones from nearby detectors. And that does not include any powered sensors you might have connected with the Honeywell 4229. There isn't a 4229U, there is a 4209U, which can add additional 2-wire smoke zones to panels that support V-Plex devices. The wiring option can be selected using a configurable Dip Switch on the module.
Dubai To Frankfurt Emirates,
Pantene Color Conditioner,
Articles OTHER