The only thing i can offer is make sure the pedal is actually moving whatever part it hooks to on the transmission beyond that I am out. B2910, LA402 FEL, Caroni TC-910 91" finish mower, RTV900. I'd be looking carefully at the wiring TO the solenoid. Kubota RTV900. You must log in or register to reply here. This has been a common problem with some of the kubota scuts, and did show up in my BX23. If you're having this problem, don't worry! 1 - 17 of 17 results. My first guess was that its a fuel issue since the starter sounded strong. Agree, start cleaning the battery cable connections at both ends, including the ground attached to the block. Probably nothing to do with it but.I have had issues in the past on a Kubota tractor and a JD mower that was caused by poorly conducting safety switches that resulted in only 7 or 8 volts getting to the starter relay and being insufficient to 'pick' the relay sufficiently to allow 12vdc to the starter motor. The only time I've ever had trouble starting my 2004 RTV 900W was when the battery was going bad. Sometimes it fires right up. L3450DT-GST, Woods FEL, B7100 HSD, FEL, 60" SB, 743 Bobcat with V2203, and more. White tiger. If a person doesn't sign in then they can't view the diagrams. Conclusion. If I keep trying the key, it eventually fires. Be sure all connections and clean and tight. Moreover, if the system has air trapped in it. Buy New Starter compatible with Kubota ATV UTV RTV 900 1000 1100 Diesel 228000-6320 18419: Starters - Amazon.com FREE DELIVERY possible on eligible purchases . As a result, we have listed the common problems faced while using Kubota RTV-X900. Parts Hotline 877-260-3528. Is the starter doing anything at all? Check if the fuel system has any water or air trapped up. I have a 2015 x900 that has a intermittent starting problem, the problem is when the key is turned to start all it does is click, after several tries it will finally fire then will be fine for a while then will do it again, checked all connections, replaced starter, replaced start relay, I am at a loss any help would be great. Yeah, that would bug me. To test safety switch 1. remove safety switch leads. Most of time it kicks right off. Has to be a load test to truly know. I emailed you guys and received a return refund authorization . I've got it to move about 5 feet a few times forward and reverse and every once in a while it will move but most of the time it will not. OrangeTractorTalks brings together Kubota enthusiasts from around the world, into one place, purpose built just for them. (when mine gave trouble) . The wd won't last so I concentrated on the spray grease. #1 I have a 2004 RTV-900 with a 3-cylinder diesel. 43 Location Rockville, md Tractor NH 33D I know this isn't the RTV forum, but no one ever posts anything over there so I'm hoping someone on this forum can help. You can order Kapper Outdoors custom merch like T shirts, turkey slate calls, box calls, diaphragm calls, duck calls and drink coasters at: https://www.cataclysmcalls.com/kapper-outdoorsEquipment list on the Kapper farm:2018 Branson 7845c tractor2017 Bobcat e42 mini excavator2016 Kubota RTV X900 diesel UTV2015 Intimidator Electric UTV2005 Kawasaki Brute Force ATV2001 Chevy 3500 dually dump truckStihl ms 362 (2) chain sawsStihl pole sawStihl HD weed whackerStihl 'regular' weed whacker The HST system is very complex so the WSM offers simple guidance in troubleshooting. I cannot speak for the newer RTV but the older ones don't have timers. Wai Global Starter Motor. As for cranking and not starting I wonder if the fuel is gelled? For a better experience, please enable JavaScript in your browser before proceeding. so i took the fuel pump off cleaned it out and still no luck. Reaction score. JavaScript is disabled. You would have to shift up and down a few times before it would actually start go. I think it's location is on the fuse cover box. Furthermore, if you try to charge the battery, it might not charge up. Will a small diesel run faster when it is running out of fuel like a chain saw does? Mechanic: Curtis B. JavaScript is disabled. JD even came out with and engineering change that supplied a low voltage relay that was added to the starting circuit because the problem was so common. Not the case on the older Kubota RTV. If this was the case then the the machine would start if the shut off system was not working correct? Failure to engage the starter would indicate solenoid failure. OrangeTractorTalks brings together Kubota enthusiasts from around the world, into one place, purpose built just for them. So continue reading to get an idea about it. It may not display this or other websites correctly. I took apart the starter it had gotten wet I rebuilt it and it works fine now. You are using an out of date browser. Same thing happened to me on my BX24, same conditions. $21.45 - $214.06. I'm not much help as far as the solenoid, but I do buy some aftermarket parts, for the tractor and other things at home. Or the air cleaner might be blocked up. Clearing trees fo. The machine sometimes, while out on terrain, you can find it difficult for the machine to slow down as you can face difficulties stopping the Kubota RTV-X900. 6 Most Common Advanced EV Golf Cart Problems, 9 Most Common John Deere 1025R Problems And Solutions, Charge the battery for a proper amount of time, and replace the battery, Clean or change the fuel tank, bleed the fuel system, Inspect the radiator for leaks or clean the radiator, Check the fuel level or bleed the fuel system, Change if the oil is old or clean the filter, Transmission issues or gear stuck in reverse, Clean the dirt formed up, align the gears to be centered and make sure you get the shifter ball back in the slot. They go bad sometimes. It has a lot of torque and is easy to drive with only two forward gears, plus neutral and reverse, making it a versatile all-around package. I'll be watching to see what you end up figuring out. If so, this is an EASY fix adjustment to cure that! Sorry two different people in two places experiencing similar problems. What causes intermittent failure of Kubota RTV 900 engine? - JustAnswer Also, the radiator should be inspected for leaks, and the dirt formed should be cleaned up. 0. However, there are technicalities and difficulties faced by the users. Brand: ESellSimple. For a better experience, please enable JavaScript in your browser before proceeding. . If it were me I would make sure the battery has a full charge first. For a better experience, please enable JavaScript in your browser before proceeding. I have a 2015 x900 that has a intermittent starting problem, the problem is when the key is turned to start all it does is click, after several tries it will finally fire then will be fine for a while then will do it again, checked all connections, replaced starter, replaced start relay, I am at a loss any help would be great bordercollie Welcome. 19K views 4 years ago In this video we replace the starter on our Kubota RTV. I'll come back and let you all know when I tare into her this weekend! Braking System Might Not Work Properly The machine sometimes, while out on terrain, you can find it difficult for the machine to slow down as you can face difficulties stopping the Kubota RTV-X900. Where should I be looking in the transmission? 113 40 miles south of Kansas City Aug 23, 2018 #2 Re: Kubota RTV 900 turns over but wont start If you have power to the lift pump but no fuel come from the discharge side of the pump, you have a pump that is not pumping (that is if you have fuel in the tank!). I had a car that acted that way. My kubota rtv 900 wont startthe lights are bright so Sometimes the cold weather can have this effect on your Kubota RTV-X900 as the flow of oil reduces in this type of weather. Mystery, RTV900 not starting - TractorByNet 6. I believe it was Doggman that had one stuck in reverse years ago collie. How to test the starter according to the manual. Moderator please delete this is there is a problem with posting it. You start at the battery and follow the negative cable to where it bolts to the frame, then follow the positive cable to the starter solenoid. In the mean time, how is your key switch? It's a 12 v mechanical "plunger arm" on my 2011 model and my 2005 that I took the picture on. WILL SHIP TOMORROW. Hi and welcome to the forum. Excavator, Tractor clearing trees! I have not taken things apart enough to see the internal spring, but I triple checked with my fingers that the arm is indeed putting tension on the solenoid to help pull it out, so I feel good about the springs. For a better experience, please enable JavaScript in your browser before proceeding. I assume since they will not start in gear, there is some sort of neutral safety switch. Yep. OrangeTractorTalks brings together Kubota enthusiasts from around the world, into one place, purpose built just for them. You are using an out of date browser. The lights came on and the horn would blow too. Kapper Outdoors, living the dream, one acre at a time. 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. The machine might not feel smooth, or the way it works might make you tired trying to control it if it seems disturbing and hard to drive. For a better experience, please enable JavaScript in your browser before proceeding. #1 This past winter I had an issue with my RTV-900 where it would not turn off. You must log in or register to reply here. I'd suggest testing it. Tennessee. Most auto parts stores can load test the battery and will do it free. We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense . Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. You have air in the lines, you must bleed all the air out at the injectors. Bordercollie, It could be a number of things according to the manual:the slow blow fuse could be blown,the safety switch -which you have checked, wiring problem- disconnected , the starter or the key switch.Then there It also says it could be the timer relay or engine stop solenoid.I got this from the trouble shooting part of the manual. Has it been wet a lot, and what year model do you have? You must log in or register to reply here. Have you checked the starter solenoid ? You are using an out of date browser. The current and voltage requirements to activate a relay are much less than what is required to activate a solenoid, so when you turn your ignition switch to start, it will activate the solenoid, and feed 12v directly from the battery, thru the fuse, thru the relay switch, to the solenoid. 1 100 td Active member As mentioned, I too would get the battery load tested. For a better experience, please enable JavaScript in your browser before proceeding. 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. This happened each of several attempts I made at starting it. I don`t want anything that goes too fast so the kids don`t get hurt and we won`t take it on the road so I think it will serve the purpose and be a real upgrade over the 2001 . Check out the picture at that link.. dated 09-09-2011, 11:27 PM There is description of symptoms and a picture I took years ago. You will have to figure out what wire that is on your machine. Sort by. http://www.messicks.com/wiki/kubota/rtv900, http://www.nettractortalk.com/forums/showthread.php?t=11383&highlight=stuck+reverse. As you look at these images keep in mind I have not worked on this engine. There is a way to test these things and I can send it to you if necessary. It's on top of the transmission ( at least on my on my "05.) Usually it would just click once when turning the key . Our Kubota 2005 RTV900 suddenly will not start. You are using an out of date browser. pybyr. What causes intermittent failure of Kubota RTV 900 engine? #1 Morning y'all! Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. Recently bought a RTV 900 Kubota, with about 620 hours on it, there's a problem with the transmission. You are using an out of date browser. ( I'm having trouble resizing the pdf on the starter but will keep trying.) If it is not pulling in with the key on the machine will not start. B2910, LA402 FEL, Caroni TC-910 91" finish mower, RTV900. Did you check it with the RTV battery? Then, periodically nothing happens. Is there any way to test the safety switch or bypass to test it to see if that is it, You can here the fuel Solniod is clicking, I took the switch off the top of the transmission the one under the linkage it has a ball bearing in it held the ball bearing in and nothing, I'll go look at mine . The fuel solenoid is powered when the engine is running. It may not display this or other websites correctly. That's frustrating. Bad connections on either side, supply or ground, could do that, but you've checked for that. recently while using it we shut it down and it wouldn't start again. Starters & Components. Are these problems related and or are there common electrical fuses read more Apr 26, 2018. Select Model. Moreover, when you start the machine, the lights may become severely dim. Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment. Hopefully this is readable. If the fuel shutoff solenoid is external it is only powered when the key is turned off, the same as a BX tractor. These include the brake system might not work properly, battery issues, starting difficulties, overheating issues, the engine might stop abruptly, low engine power, smoothness issues, and transmission issues. Other times, it just clicks like the battery is dead. It was an easy swap out and all was good until a month ago when the new stop solenoid died in the same manner; meaning the vehicle would not turn off with the key and I had to close the fuel shutoff with my finger to shutdown the vehicle. This is caused by excessive voltage drop between your ignition switch and the solenoid. For a better experience, please enable JavaScript in your browser before proceeding. $11236. if so I agree with DT86, your fuel has jelled somewhere. Voltage doesn't give the starter power. bordercollie. #1 Recently bought a RTV 900 Kubota, with about 620 hours on it, there's a problem with the transmission. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. But napa says nothing is wrong with it and kubota wants 500.00 for one what do you guys think, I just keep coming back to the battery since Napa did the starter check on their system.
Kyndryl Joining Bonus,
American Girl: Samantha Book,
Articles K